Temperature correction of spectra to improve solute concentration monitoring by in situ ultraviolet and mid-infrared spectrometries towards isothermal local model performance
Chong, Magdalene W.S. and McGlone, Thomas and Chai, Ching Yee and Briggs, Naomi E. B. and Brown, Cameron J. and Perciballi, Francesca and Dunn, Jaclyn and Parrott, Andrew J. and Dallin, Paul and Andrews, John and Nordon, Alison and Florence, Alastair J. (2022) Temperature correction of spectra to improve solute concentration monitoring by in situ ultraviolet and mid-infrared spectrometries towards isothermal local model performance. Organic Process Research and Development, 26 (11). pp. 3096-3105. ISSN 1083-6160 (https://doi.org/10.1021/acs.oprd.2c00238)
Preview |
Text.
Filename: Chong_etal_OPRD_2022_Temperature_correction_of_spectra_to_improve_solute_concentration.pdf
Final Published Version License: Download (3MB)| Preview |
Abstract
Changes in temperature can significantly affect spectroscopic-based methods for in situ monitoring of processes. As varying temperature is inherent to many processes, associated temperature effects on spectra are unavoidable, which can hinder solute concentration determination. Ultraviolet (UV) and mid-infrared (IR) data were acquired for l-ascorbic acid (LAA) in MeCN/H2O (80:20 w/w) at different concentrations and temperatures. For both techniques, global partial least squares (PLS) models for prediction of LAA concentration constructed without preprocessing of the spectra required a high number of latent variables to account for the effects of temperature on the spectra (root mean square error of cross validation (RMSECV) of 0.18 and 0.16 g/100 g solvent, for UV and IR datasets, respectively). The PLS models constructed on the first derivative spectra required fewer latent variables, yielding variable results in accuracy (RMSECV of 0.23 and 0.06 g/100 g solvent, respectively). Corresponding isothermal local models constructed indicated improved model performance that required fewer latent variables in the absence of temperature effects (RMSECV of 0.01 and 0.04 g/100 g solvent, respectively). Temperature correction of the spectral data via loading space standardization (LSS) enabled the construction of global models using the same number of latent variables as the corresponding local model, which exhibited comparable model performance (RMSECV of 0.06 and 0.04 g/100 g solvent, respectively). The additional chemometric effort required for LSS is justified if prediction of solute concentration is required for in situ monitoring and control of cooling crystallization with an accuracy and precision approaching that attainable using an isothermal local model. However, the model performance with minimal preprocessing may be sufficient, for example, in the early phase development of a cooling crystallization process, where high accuracy is not always required. UV and IR spectrometries were used to determine solubility diagrams for LAA in MeCN/H2O (80:20 w/w), which were found to be accurate compared to those obtained using the traditional techniques of transmittance and gravimetric measurement. For both UV and IR spectrometries, solubility values obtained from models with LSS temperature correction were in better agreement with those determined gravimetrically. In this first example of the application of LSS to UV spectra, significant improvement in the predicted solute concentration is achieved with the additional chemometric effort. There is no extra experimental burden associated with the use of LSS if a structured approach is employed to acquire calibration data that account for both temperature and concentration.
ORCID iDs
Chong, Magdalene W.S., McGlone, Thomas ORCID: https://orcid.org/0000-0002-9897-1790, Chai, Ching Yee, Briggs, Naomi E. B., Brown, Cameron J. ORCID: https://orcid.org/0000-0001-7091-1721, Perciballi, Francesca, Dunn, Jaclyn, Parrott, Andrew J. ORCID: https://orcid.org/0000-0002-4598-2736, Dallin, Paul, Andrews, John, Nordon, Alison ORCID: https://orcid.org/0000-0001-6553-8993 and Florence, Alastair J. ORCID: https://orcid.org/0000-0002-9706-8364;-
-
Item type: Article ID code: 83120 Dates: DateEvent18 November 2022Published4 November 2022Published Online20 October 2022AcceptedSubjects: Science > Chemistry > Organic chemistry Department: Faculty of Science > Pure and Applied Chemistry
Faculty of Science > Strathclyde Institute of Pharmacy and Biomedical Sciences
Strategic Research Themes > Measurement Science and Enabling Technologies
Strategic Research Themes > Advanced Manufacturing and Materials
Technology and Innovation Centre > Continuous Manufacturing and Crystallisation (CMAC)Depositing user: Pure Administrator Date deposited: 08 Nov 2022 15:12 Last modified: 11 Nov 2024 13:40 URI: https://strathprints.strath.ac.uk/id/eprint/83120