Lightning protection for a temporary structure in open area
Jacob, Satheesh and Basharat, Nadeem and Siew, W.H. and Choi, Seungjae (2016) Lightning protection for a temporary structure in open area. In: 33rd International Conference on Lightning Protection, 2016-09-25 - 2016-09-30, Estoril Congress Center.
Preview |
Text.
Filename: Jacob_etal_2016_lightning_protection_of_a_temporary_structure_in_open_area.pdf
Accepted Author Manuscript Download (276kB)| Preview |
Abstract
The current lightning protection systems are well proven and widely deployed for general situation. However, the methodology may be inadequate when applied to various situations especially in open area because the current BS EN and international standards do not cover guidance or procedures for lightning protection in open areas. The fundamental principle of lightning safety is ‘No place outside is safe when thunderstorms are in the area!’ The purpose of this research is to provide an outline of the lightning protection system strategy for the protection of life, livestock, sensitive equipment and property in open areas. The research proposes alternative methodology that can be used in open area for safety rather than the No-Notice personal backcountry lightning risk reduction process. Based on the results a suitable protection mechanism shall be developed to concept stage
ORCID iDs
Jacob, Satheesh, Basharat, Nadeem, Siew, W.H. ORCID: https://orcid.org/0000-0003-4000-6856 and Choi, Seungjae;-
-
Item type: Conference or Workshop Item(Paper) ID code: 56942 Dates: DateEvent25 September 2016Published27 May 2016AcceptedSubjects: Technology > Electrical engineering. Electronics Nuclear engineering Department: Faculty of Engineering > Electronic and Electrical Engineering Depositing user: Pure Administrator Date deposited: 12 Jul 2016 10:35 Last modified: 20 Dec 2024 02:28 Related URLs: URI: https://strathprints.strath.ac.uk/id/eprint/56942