Investigation of synthetic aperture methods in ultrasound surface imaging using elementary surface types
Kerr, W. and Pierce, S. G. and Rowe, P. (2016) Investigation of synthetic aperture methods in ultrasound surface imaging using elementary surface types. Ultrasonics, 72. pp. 165-176. ISSN 0041-624X (https://doi.org/10.1016/j.ultras.2016.08.007)
Preview |
Text.
Filename: Kerr_etal_Ultrasonics2016_Synthetic_aperture_methods_in_ultrasound_surface_imaging.pdf
Accepted Author Manuscript License: Download (1MB)| Preview |
Abstract
Synthetic aperture imaging methods have been employed widely in recent research in non-destructive testing (NDT), but uptake has been more limited in medical ultrasound imaging. Typically offering superior focussing power over more traditional phased array methods, these techniques have been employed in NDT applications to locate and characterise small defects within large samples, but have rarely been used to image surfaces. A desire to ultimately employ ultrasonic surface imaging for bone surface geometry measurement prior to surgical intervention motivates this research, and results are presented for initial laboratory trials of a surface reconstruction technique based on global thresholding of ultrasonic 3D point cloud data. In this study, representative geometry artefacts were imaged in the laboratory using two synthetic aperture techniques; the Total Focusing Method (TFM) and the Synthetic Aperture Focusing Technique (SAFT) employing full and narrow synthetic apertures, respectively. Three high precision metallic samples of known geometries (cuboid, sphere and cylinder) which featured a range of elementary surface primitives were imaged using a 5MHz, 128 element 1D phased array employing both SAFT and TFM approaches. The array was manipulated around the samples using a precision robotic positioning system, allowing for repeatable ultrasound derived 3D surface point clouds to be created. A global thresholding technique was then developed that allowed the extraction of the surface profiles, and these were compared with the known geometry samples to provide a quantitative measure of error of 3D surface reconstruction. The mean errors achieved with optimised SAFT imaging for the cuboidal, spherical and cylindrical samples were 1.3 mm, 2.9 mm and 2.0 mm respectively, while those for TFM imaging were 3.7 mm, 3.0 mm and 3.1 mm, respectively. These results were contrary to expectations given the higher information content associated with the TFM images. However, it was established that the reduced error associated with the SAFT technique was associated with significant reductions in side lobe levels of approximately 24dB in comparison to TFM imaging, although this came at the expense of reduced resolution and coverage.
ORCID iDs
Kerr, W., Pierce, S. G. ORCID: https://orcid.org/0000-0003-0312-8766 and Rowe, P. ORCID: https://orcid.org/0000-0002-4877-8466;-
-
Item type: Article ID code: 57506 Dates: DateEvent31 December 2016Published15 August 2016Published Online11 August 2016AcceptedSubjects: Technology > Electrical engineering. Electronics Nuclear engineering
Medicine > Medicine (General)Department: Faculty of Engineering > Biomedical Engineering
Faculty of Engineering > Electronic and Electrical EngineeringDepositing user: Pure Administrator Date deposited: 23 Aug 2016 09:10 Last modified: 22 Dec 2024 01:18 URI: https://strathprints.strath.ac.uk/id/eprint/57506