Picture of DNA strand

Pioneering chemical biology & medicinal chemistry through Open Access research...

Strathprints makes available scholarly Open Access content by researchers in the Department of Pure & Applied Chemistry, based within the Faculty of Science.

Research here spans a wide range of topics from analytical chemistry to materials science, and from biological chemistry to theoretical chemistry. The specific work in chemical biology and medicinal chemistry, as an example, encompasses pioneering techniques in synthesis, bioinformatics, nucleic acid chemistry, amino acid chemistry, heterocyclic chemistry, biophysical chemistry and NMR spectroscopy.

Explore the Open Access research of the Department of Pure & Applied Chemistry. Or explore all of Strathclyde's Open Access research...

Detection of potentially toxic metals by SERS using salen complexes

Docherty, Julie Ann and Mabbott, Samuel and Smith, W E and Faulds, Karen and Davidson, C M and Reglinski, J and Graham, Duncan (2016) Detection of potentially toxic metals by SERS using salen complexes. Analyst. ISSN 0003-2654

[img]
Preview
Text (Docherty-etal-Analyst2016-Detection-of-potentially-toxic-metals-by-SERS)
Docherty_etal_Analyst2016_Detection_of_potentially_toxic_metals_by_SERS.pdf
Accepted Author Manuscript

Download (1MB) | Preview

Abstract

Surfaced enhanced Raman scattering (SERS) can discriminate between metal complexes due to the characteristic “spectral fingerprints” obtained. As a result, SERS has the potential to develop relatively simple and sensitive methods of detecting and quantifying a range of metal ions in solution. This could be beneficial for the environmental monitoring of potentially toxic metals (PTMs). Here, salen (C16H16N2O2) was used as a ligand to form complexes of Ni(II), Cu(II), Mn(II) and Co(II) in solution. The SERS spectra showed characteristic spectral differences specific to each metal complex, thus allowing the identification of each of these metal ions. This method allows a number of metal ions to be detected using the same ligand and an identical preparation procedure. The limit of detection (LOD) was determined for each metal ion, and it was found that Ni(II), Cu(II) and Mn(II) could be detected below the WHO’s recommended limits in drinking water at 1, 2 and 2 µg L-1, respectively. Co(II) was found to have an LOD of 20 µg L-1, however no limit has been set for this ion by the WHO as the concentration of Co(II) in drinking water is generally <1-2 μg L-1. A contaminated water sample was also analysed where Mn(II) was detected at a level of 800 µg L-1.