Preliminary assessment of three protocols for the screening of amblyopia through Monte Carlo simulation
Shand, Keely and Boribalburephan, Atirut and Giardini, Mario Ettore; (2024) Preliminary assessment of three protocols for the screening of amblyopia through Monte Carlo simulation. In: Proceedings of the IEEE International Instrumentation and Measurement Technology Conference (I2MTC) 2024. Proceedings of the IEEE International Instrumentation and Measurement Technology Conference (I2MTC) . IEEE, GBR, pp. 1-5. ISBN 9798350380903 (https://doi.org/10.1109/I2MTC60896.2024.10560914)
Preview |
Text.
Filename: Shand-etal-I2MTC-2024-Preliminary-assessment-of-three-protocols-for-the-screening-of-amblyopia-through-Monte-Carlo-simulation.pdf
Accepted Author Manuscript License: Strathprints license 1.0 Download (1MB)| Preview |
Abstract
Amblyopia is a neurodevelopmental disorder that causes irreversible vision loss in one eye. In order to be effective, treatment needs to start as early as possible, ideally in early infancy. The screening for amblyopia assesses the disparity of the child’s visual acuity (VA). In pre-verbal children, this screening is performed using a preferential looking test. These testing protocols rely on a subjective estimate by the test operator of the child’s attention, and this estimate is subject to errors. Little is understood of the quantitative impact of error rates on screening performance. In this paper, a Monte Carlo simulation to compare the clinical performance of three preferential-looking test protocols for paediatric VA screening tests for amblyopia is described. The inter-protocol differences of “Cardiff Acuity Test” (CAT), “Keeler Acuity Cards for Infants” (KACI) and “Teller Acuity Cards” (TAC) are assessed by iteratively executing through a simulation loop of an examiner testing a test subject using the three set protocols. The measured VA from each protocol and the actual VA have been compared using Bland-Altman statistics. It was determined that CAT and KACI both have a systematic bias, whereby they measure the VA at a greater logMAR value than the smallest testing resolution. KACI bias is greater due to the greater step size used.
ORCID iDs
Shand, Keely ORCID: https://orcid.org/0000-0002-6997-671X, Boribalburephan, Atirut and Giardini, Mario Ettore ORCID: https://orcid.org/0000-0003-4849-9683;-
-
Item type: Book Section ID code: 89357 Dates: DateEvent28 June 2024Published23 May 2024Published Online24 January 2024AcceptedNotes: © 2024 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting /republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. Subjects: Technology > Electrical engineering. Electronics Nuclear engineering
Medicine > Biomedical engineering. Electronics. InstrumentationDepartment: Faculty of Engineering > Biomedical Engineering
Strategic Research Themes > Health and WellbeingDepositing user: Pure Administrator Date deposited: 24 May 2024 09:40 Last modified: 11 Nov 2024 15:35 Related URLs: URI: https://strathprints.strath.ac.uk/id/eprint/89357