Transient spark discharges in high velocity airflow

Macpherson, Ruairidh W. and Timoshkin, Igor V. and Wilson, Mark P. and Burt, Graeme M. (2024) Transient spark discharges in high velocity airflow. IEEE Transactions on Plasma Science, 52 (3). pp. 816-823. ISSN 1939-9375 (https://doi.org/10.1109/TPS.2024.3379834)

[thumbnail of Macpherson-etal-IEEE-TPS-2024-Transient-spark-discharges-in-high-velocity-airflow]
Preview
Text. Filename: Macpherson-etal-IEEE-TPS-2024-Transient-spark-discharges-in-high-velocity-airflow.pdf
Accepted Author Manuscript
License: Creative Commons Attribution 4.0 logo

Download (1MB)| Preview

Abstract

Air-filled, self-breakdown plasma closing switches can operate at high pulse repetition frequency, when overstressed with HVDC voltage. However, their recovery characteristics, breakdown voltage, the achievable pulse repetition rate and variation in this rate are affected by the thermal effects local to the electrodes and by gas by-products generated by spark discharges. As a potential improvement to the performance of plasma closing switches, flowing gas can be forced through the inter-electrode gap. In this paper, it was shown that purging an inter-electrode gap of the plasma closing switch with air is a viable way of controlling the pulse repetition rate and variation of this rate. It was found that the difference between breakdown voltages of the first (single) breakdown events in static air and at 100 m/s air flow was less than 10%. In static air, the breakdown voltage of repetitive breakdown events decreases after the first and reaches its saturation value. It was shown that introduction of the air flow at 100 m/s leads to recovery of the repetitive breakdown voltage, which could reach its new saturation value, up to 30% higher than the first recorded breakdown voltage. Also, purging of the spark gap with air resulted in decreasing the pulse repetition rate, however it leads to higher breakdown voltage, lower variation in pulse repetition rate and increasing plasma conductivity in the spark channel, thereby increasing the efficiency of the overall high voltage system via reduced switching losses.

ORCID iDs

Macpherson, Ruairidh W. ORCID logoORCID: https://orcid.org/0000-0002-0264-6943, Timoshkin, Igor V. ORCID logoORCID: https://orcid.org/0000-0002-0380-9003, Wilson, Mark P. ORCID logoORCID: https://orcid.org/0000-0003-3088-8541 and Burt, Graeme M. ORCID logoORCID: https://orcid.org/0000-0002-0315-5919;

Persistent Identifier

https://doi.org/10.17868/strath.00088612