Equivalent electrical circuit derivation of a 7MW offshore wind turbine gearbox

Jaen-Sola, P. and McDonald, A. S. (2018) Equivalent electrical circuit derivation of a 7MW offshore wind turbine gearbox. The Journal of Engineering.

[thumbnail of Jaen-Sola-McDonald-JOE-2018-Equivalent-electrical-circuit-derivation-of-a-7MW-offshore]
Preview
Text. Filename: Jaen_Sola_McDonald_JOE_2018_Equivalent_electrical_circuit_derivation_of_a_7MW_offshore.pdf
Accepted Author Manuscript

Download (582kB)| Preview

Abstract

A thermal model of the main mechanical components of the Levenmouth Development Turbine powertrain has been developed in Matlab/Simulink in order to predict their efficiency curve as a function of torque and speed and their electrical analogues of current and frequency. A parametric loss estimation method has been adapted to the turbine gearbox architecture, its oil type and temperature and used to calculate the load and non-load dependent losses due to bearing, mesh, seal, churning and windage and pump losses. The gearbox losses have been expressed as notional equivalent electrical circuit parameters.