Microstructural characteristics of electrodeposited damascene copper lines
Konkova, T.N. and Mironov, S. Yu and Ke, Y. and Ohnuki, J. (2014) Microstructural characteristics of electrodeposited damascene copper lines. Letters on Materials, 4 (2). pp. 104-107. ISSN 2410-3535 (https://doi.org/10.22226/2410-3535-2014-2-104-107)
Preview |
Text.
Filename: Konkova_LM2014_Microstructural_characteristics_of_electrodeposited_damascene_copper_lines.pdf
Final Published Version License: Download (1MB)| Preview |
Abstract
The high-resolution electron backscatter diffraction technique and transmission electron microscopy were applied to study microstructure in the overburden layer, in upper and bottom parts of as-deposited as well as subsequently annealed nanoscale (100 nm width) copper wires. It was shown that the temperature interval 100oC-200oC should be seen as a transition period of microstructure evolution in damascene copper lines.
ORCID iDs
Konkova, T.N. ORCID: https://orcid.org/0000-0001-7495-7495, Mironov, S. Yu, Ke, Y. and Ohnuki, J.;-
-
Item type: Article ID code: 58515 Dates: DateEventApril 2014PublishedSubjects: Technology > Manufactures Department: Faculty of Engineering > Design, Manufacture and Engineering Management Depositing user: Pure Administrator Date deposited: 09 Nov 2016 12:02 Last modified: 11 Nov 2024 11:33 URI: https://strathprints.strath.ac.uk/id/eprint/58515