Ultimate strength of bolted moment-connections between cold-formed steel members
Lim, J.B.P. and Nethercot, D.A. (2003) Ultimate strength of bolted moment-connections between cold-formed steel members. Thin-Walled Structures, 41 (11). pp. 1019-1039. ISSN 0263-8231 (http://dx.doi.org/10.1016/S0263-8231(03)00045-4)
Full text not available in this repository.Request a copyAbstract
The behaviour and design of bolted moment-connections between cold-formed steel members, formed by using brackets bolted to the webs of the section, is considered. The particular problem of the moment-capacity of such joints being lower than that of the cold-formed steel sections being connected because of web buckling, caused by the concentration of load transfer from the bolts, is addressed. In this paper, a combination of laboratory tests and finite element analyses is used to investigate this mode of failure. It is demonstrated that there is good agreement between the measured ultimate moment-capacity and that predicted by using the finite element method. A parametric study conducted using the finite element model shows that the moment-capacity of a practical size joint can be up to 20% lower than that of the cold-formed steel sections being connected. Web buckling so-caused must therefore be considered in the design of such connections.
-
-
Item type: Article ID code: 4816 Dates: DateEventNovember 2003PublishedSubjects: Technology > Engineering (General). Civil engineering (General) Department: Faculty of Engineering > Civil and Environmental Engineering Depositing user: Strathprints Administrator Date deposited: 10 Dec 2007 Last modified: 29 Nov 2024 01:03 URI: https://strathprints.strath.ac.uk/id/eprint/4816