Experimental operation of a cyclotron autoresonance maser oscillator at the second harmonic

Cooke, S J and Cross, A W and He, W and Phelps, A D R (1996) Experimental operation of a cyclotron autoresonance maser oscillator at the second harmonic. Physical Review Letters, 77 (23). pp. 4836-4839. ISSN 1079-7114 (https://doi.org/10.1103/PhysRevLett.77.4836)

Full text not available in this repository.Request a copy

Abstract

Experimental results are presented of the first cyclotron autoresonance maser oscillator operated using the second harmonic of the cyclotron frequency. An interaction efficiency of 3.9% has been measured at a frequency of 14.27 GHz, using an 80 ns pulsed, 14 A electron beam of energy 300 keV, to produce a coherent microwave power of 170 kW. Emission occurred at 3.7 times the relativistic cyclotron frequency, due to the large Doppler frequency increase and second harmonic interaction.

ORCID iDs

Cooke, S J, Cross, A W ORCID logoORCID: https://orcid.org/0000-0001-7672-1283, He, W ORCID logoORCID: https://orcid.org/0000-0001-7018-0527 and Phelps, A D R ORCID logoORCID: https://orcid.org/0000-0002-1100-1012;