Enhanced phased array imaging through reverberating interfaces

Ingram, Marcus and Gachagan, Anthony and Mulholland, Anthony J. and Nordon, Alison and Dziewierz, Jerzy and Hegarty, Martin; (2019) Enhanced phased array imaging through reverberating interfaces. In: 45th Annual Review Of Progress In Quantitative Nondestructive Evaluation. AIP Conference Proceedings, 38 . AIP, USA. ISBN 9780735418325 (https://doi.org/10.1063/1.5099833)

[thumbnail of Ingram-etal-AIPCP2019-Enhanced-phased-array-imaging-through-reverberating-interfaces]
Preview
Text. Filename: Ingram_etal_AIPCP2019_Enhanced_phased_array_imaging_through_reverberating_interfaces.pdf
Accepted Author Manuscript

Download (290kB)| Preview

Abstract

A key challenge to achieve non-invasive industrial process analysis is the transmission of information through the vessel wall. Typical non-invasive technologies, such as Raman spectroscopy, require an optically transparent 'window' into the process to acquire the process data. In this work, ultrasonic phased arrays were used to image a dynamic process through planar steel vessel walls into a fluid load. Due to the acoustic impedance mismatch at the steel-fluid interface, only a small fraction of the excitation energy comes back to the receiver in the form of useful echoes from the process. Also, the ultrasonic energy that is not transmitted across the steel-fluid interface reverberates within the vessel wall, masking signals that are reflected from within the process. Here, the ultrasonic array was deployed using Full Matrix Capture (FMC) followed by the Total Focusing Method (TFM) that focusses the ultrasonic beam at every pixel in the image. However, the TFM algorithm is not spatial resolved, leading to multiples of the reverberations interfering throughout the desired image region. To extract the signals corresponding to the process fluid, a method has been developed called the Reverberation Pattern Gain Correction Method (RP-GCM). Firstly, the algorithm uses ray-tracing to predict the path length of reverberations from the steel-fluid interface. The signals in the FMC data set corresponding to those reverberations are then windowed and a gain filter applied, prior to application of the regular TFM process. The RP-GCM has been applied to a simulated FMC data set, developed in PZFlex (OnScale, USA). Initial results demonstrate the effectiveness of this method in separating the vessel reverberations from the ultrasonic echoes of interest relating to the process.

ORCID iDs

Ingram, Marcus ORCID logoORCID: https://orcid.org/0000-0002-1985-3359, Gachagan, Anthony ORCID logoORCID: https://orcid.org/0000-0002-9728-4120, Mulholland, Anthony J. ORCID logoORCID: https://orcid.org/0000-0002-3626-4556, Nordon, Alison ORCID logoORCID: https://orcid.org/0000-0001-6553-8993, Dziewierz, Jerzy ORCID logoORCID: https://orcid.org/0000-0001-6954-8224 and Hegarty, Martin;