Non-invasive computer-assisted measurement of knee alignment
Clarke, Jon V and Riches, Philip E and Picard, Frederic and Deakin, Angela H (2012) Non-invasive computer-assisted measurement of knee alignment. Computer Aided Surgery, 17 (1). pp. 29-39. ISSN 1097-0150 (https://doi.org/10.3109/10929088.2011.635217)
Preview |
PDF.
Filename: submitted_paper.pdf
Preprint Download (332kB)| Preview |
Abstract
The quantification of knee alignment is a routine part of orthopaedic practice and is important for monitoring disease progression, planning interventional strategies, and follow-up of patients. Currently available technologies such as radiographic measurements have a number of drawbacks. The aim of this study was to validate a potentially improved technique for measuring knee alignment under different conditions. An image-free navigation system was adapted for non-invasive use through the development of external infrared tracker mountings. Stability was assessed by comparing the variance (F-test) of repeated mechanical femoro-tibial (MFT) angle measurements for a volunteer and a leg model. MFT angles were then measured supine, standing and with varus-valgus stress in asymptomatic volunteers who each underwent two separate registrations and repeated measurements for each condition. The mean difference and 95% limits of agreement were used to assess intra-registration and inter-registration repeatability. For multiple registrations the range of measurements for the external mountings was 1° larger than for the rigid model with statistically similar variance (p=0.34). Thirty volunteers were assessed (19 males, 11 females) with a mean age of 41 years (range: 20-65) and a mean BMI of 26 (range: 19-34). For intra-registration repeatability, consecutive coronal alignment readings agreed to almost ±1°, with up to ±0.5° loss of repeatability for coronal alignment measured before and after stress maneuvers, and a ±0.2° loss following stance trials. Sagittal alignment measurements were less repeatable overall by an approximate factor of two. Inter-registration agreement limits for coronal and sagittal supine MFT angles were ±1.6° and ±2.3°, respectively. Varus and valgus stress measurements agreed to within ±1.3° and ±1.1°, respectively. Agreement limits for standing MFT angles were ±2.9° (coronal) and ±5.0° (sagittal), which may have reflected a variation in stance between measurements. The system provided repeatable, real-time measurements of coronal and sagittal knee alignment under a number of dynamic, real-time conditions, offering a potential alternative to radiographs.
ORCID iDs
Clarke, Jon V ORCID: https://orcid.org/0000-0003-4499-7183, Riches, Philip E ORCID: https://orcid.org/0000-0002-7708-4607, Picard, Frederic and Deakin, Angela H;-
-
Item type: Article ID code: 34539 Dates: DateEvent2012Published30 November 2011Published OnlineSubjects: Technology > Engineering (General). Civil engineering (General) > Bioengineering Department: Faculty of Engineering > Biomedical Engineering Depositing user: Pure Administrator Date deposited: 26 Oct 2011 10:34 Last modified: 11 Nov 2024 09:53 Related URLs: URI: https://strathprints.strath.ac.uk/id/eprint/34539