Multiresolution models of DC traction power supply systems with reversible substations
Fan, Fulin and Li, Yafang and Ziani, Smail and Stewart, Brian G. (2024) Multiresolution models of DC traction power supply systems with reversible substations. IET Electrical Systems in Transportation, 2024 (1). 8279648. ISSN 2042-9738 (https://doi.org/10.1049/2024/8279648)
Preview |
Text.
Filename: Fan-etal-IET-EST-2024-Multiresolution-models-of-DC-traction-power-supply-systems.pdf
Final Published Version License: Download (3MB)| Preview |
Abstract
Reversible substations (RSs) permitting bidirectional power flows can recover the regenerative braking energy of trains in DC traction power supply systems (TPSSs), increasing the energy efficiency of railway systems. To predict their effects on system dynamics and energy savings, the paper develops multiresolution models (MRMs) to simulate the RS roles with different fidelities. A high-resolution model for the transient simulation replicates a particular topology where a three-level voltage source inverter is connected to the secondary winding of an existing 12-pulse rectifier transformer and regulated to keep a constant DC voltage in the inverting mode. Furthermore, it can model the transient effects of pantograph-to-line arcing by inserting arc voltage profiles at the train’s input stage. To increase the computation speed in the long-term energy flow simulation, a low-resolution model simplifies the rectifiers into a series connection of a diode and a controlled voltage source depicting their nonlinear output characteristics and then places a DC voltage source in parallel to form a reverse path for braking power recovery. In addition, nonlinear conversion efficiencies are introduced to calculate energy flows across substations. The MRMs are tested based on a 1.5 kV DC TPSS and discussed alongside system dynamics under normal operation or pantograph arcing and the consistencies between different models. The RS using bidirectional voltage source converters only is additionally modelled to compare the technical performance of the two topologies in terms of system dynamics and energy efficiencies.
ORCID iDs
Fan, Fulin ORCID: https://orcid.org/0000-0003-2450-6877, Li, Yafang, Ziani, Smail and Stewart, Brian G.;-
-
Item type: Article ID code: 91617 Dates: DateEvent21 October 2024Published21 October 2024Published Online1 September 2024AcceptedSubjects: Technology > Electrical engineering. Electronics Nuclear engineering Department: Faculty of Engineering > Electronic and Electrical Engineering Depositing user: Pure Administrator Date deposited: 18 Dec 2024 13:57 Last modified: 20 Dec 2024 09:47 URI: https://strathprints.strath.ac.uk/id/eprint/91617