Enabling quantification of protein concentration in human serum biopsies using attenuated total reflectance – Fourier transform infrared (ATR-FTIR) spectroscopy
Spalding, Katie and Bonnier, Franck and Bruno, Clément and Blasco, Hélène and Board, Ruth and Benz-de Bretagne, Isabelle and Byrne, Hugh J. and Butler, Holly J. and Chourpa, Igor and Radhakrishnan, Pretheepan and Baker, Matthew J. (2018) Enabling quantification of protein concentration in human serum biopsies using attenuated total reflectance – Fourier transform infrared (ATR-FTIR) spectroscopy. Vibrational Spectroscopy, 99. pp. 50-58. ISSN 0924-2031 (https://doi.org/10.1016/j.vibspec.2018.08.019)
Preview |
Text.
Filename: Spalding_etal_VS_2018_Enabling_quantification_of_protein_concentration_in_human_serum_biopsies_using.pdf
Accepted Author Manuscript License: Download (1MB)| Preview |
Abstract
Changes in protein concentrations within human blood are used as an indicator for nutritional state, hydration and underlying illnesses. They are often measured at regular clinical appointments and the current analytical process can result in long waiting times for results and the need for return patient visits. Attenuated total reflectance – Fourier transform infrared (ATR-FTIR) spectroscopy has the ability to detect minor molecular differences, qualitatively and quantitatively, in biofluid samples, without extensive sample preparation. ATR-FTIR can return an analytical measurement almost instantaneously and therefore could be deemed as an ideal technique for monitoring molecular alterations in blood within the clinic. To determine the suitability of using ATR-FTIR spectroscopy to enable protein quantification in a clinical setting, pooled human serum samples spiked with varying concentrations of human serum albumin (HSA) and immunoglobulin G (IgG) were analysed, before analysing patient clinical samples. Using a validated partial least squares method, the spiked samples (IgG) produced a linearity as high as 0.998 and a RMSEV of 0.49 ± 0.05 mg mL−1, with the patient samples producing R2 values of 0.992 and a corresponding RMSEV of 0.66 ± 0.05 mg mL−1. This claim was validated using two blind testing models, leave one patient out cross validation and k-fold cross validation, achieving optimum linearity and RMSEV values of 0.934 and 1.99 ± 0.79 mg mL−1, respectively. This demonstrates that ATR-FTIR is able to quantify protein within clinically relevant complex matrices and concentrations, such as serum samples, rapidly and with simple sample preparation. The ability to provide a quantification step, along with rapid disease classification, from a spectroscopic signature will aid clinical translation of vibrational spectroscopy to assist with problems currently faced with patient diagnostic pathways.
ORCID iDs
Spalding, Katie ORCID: https://orcid.org/0000-0002-3842-2765, Bonnier, Franck, Bruno, Clément, Blasco, Hélène, Board, Ruth, Benz-de Bretagne, Isabelle, Byrne, Hugh J., Butler, Holly J., Chourpa, Igor, Radhakrishnan, Pretheepan ORCID: https://orcid.org/0000-0002-6057-8432 and Baker, Matthew J. ORCID: https://orcid.org/0000-0003-2362-8581;-
-
Item type: Article ID code: 66060 Dates: DateEvent30 November 2018Published1 September 2018Published Online25 August 2018AcceptedSubjects: Science > Chemistry Department: Faculty of Science > Pure and Applied Chemistry
Faculty of Engineering > Biomedical EngineeringDepositing user: Pure Administrator Date deposited: 09 Nov 2018 14:06 Last modified: 27 Nov 2024 04:35 Related URLs: URI: https://strathprints.strath.ac.uk/id/eprint/66060