Radiometric detection and analysis of arcing faults
Harris, Rachel M. and Judd, Martin D. and Moore, Philip J. and Livie, James (2015) Radiometric detection and analysis of arcing faults. IEEE Transactions on Dielectrics and Electrical Insulation, 22 (3). pp. 1547-1558. 7116350. ISSN 1070-9878 (https://doi.org/10.1109/TDEI.2015.7116350)
Full text not available in this repository.Request a copyAbstract
A novel method for long-range detection and potential location of arcing faults on electrical distribution networks is described and investigated. When a network fault induces an electrical arc it is accompanied by the radiation of electromagnetic transients that can be detected remotely as a radio frequency signal. By capturing its wavefront at more than one monitoring location the time-difference-of-arrival between monitoring station pairs can be used to establish the origin. This approach is used to locate lightning arcs where the emissions are referred to as sferics. A key advantage of detecting faults by capturing the radiometric emissions from their arcs is that no direct connection is required to the plant being monitored, eliminating the need to take it out of service for either installation or maintenance of the radiometric monitoring equipment. This approach also has the potential for wide area coverage as opposed to monitoring a single specific circuit. In this paper, we describe the development and trialing of a monitoring network comprising 4 geographically separate receiving stations with an inter-station distance of less than 20 km. The utilization of GPS steered time-stamps overcame the fundamental challenge of providing a common, accurate, synchronized time-stamp for the transient signals received at each station. As well as providing the basis for fault location, this information allowed signals to be correlated with the network fault records. The system was proven to capture emissions from fault-induced arcs, but none of the captures were made at more than a single monitoring station, hence the efficacy of the system at locating fault-induced arcs could not be evaluated. However, lightning strikes were captured simultaneously at several monitoring stations and successfully located; demonstrating that the data capture methodology does allow signal origins to be determined. Further study is needed regarding the propagation distances of fault induced radiometric emissions, particularly their rate of attenuation with distance.
-
-
Item type: Article ID code: 54771 Dates: DateEvent1 June 2015Published28 November 2014AcceptedSubjects: Technology > Electrical engineering. Electronics Nuclear engineering Department: Faculty of Engineering > Electronic and Electrical Engineering
University of Strathclyde > University of StrathclydeDepositing user: Pure Administrator Date deposited: 11 Dec 2015 01:33 Last modified: 11 Nov 2024 11:14 Related URLs: URI: https://strathprints.strath.ac.uk/id/eprint/54771