A new electrostatic transducer incorporating fluidic amplification
Campbell, Ewan Fraser and Galbraith, Walter and Hayward, Gordon; (2007) A new electrostatic transducer incorporating fluidic amplification. In: 2006 IEEE Ultrasonics Symposium. Ultrasonics symposium . IEEE, New York, pp. 1445-1448. ISBN 1424402018 (https://doi.org/10.1109/ULTSYM.2006.364)
Full text not available in this repository.Request a copyAbstract
A methodology for improving the performance of electrostatic transducers that comprise a thin membrane positioned above a conducting backplate is presented. The concept has its foundations in the normally tubular sections used for amplification of sound in musical instruments, where the resonant frequency of a fluid filled conduit is determined by the conduit length. Finite Element Modelling was used to evaluate a range of potential configurations, including conduit aspect ratio and the membrane - cavity structure immediately above the conduit (ie membrane dimensions, cavity width and depth). Results are presented that reveal the potential variation in amplification and these demonstrate that under certain conditions, a very significant improvement can be obtained. For example, at a centre frequency of 215kHz, a conduit with an aspect ratio of 10:1 will produce a tenfold increase in displacement at the membrane end of the system. Although this is achievable over a wide frequency range, the best overall performance in terms of absolute sound pressure level was obtained when the length of the conduit was matched to the centre frequency of the vibrating membrane. Proof of concept devices were manufactured and tested experimentally, for both quarter wavelength and half wavelength conditions. Laser vibrometry was used to measure the displacement of the membrane, while a calibrated PVDF hydrophone and electret microphone were employed to measure the acoustic output at the end of the conduit. The presence of the vibrating air conduits was observed to increase the measured acoustic output by a factor greater than 20dB. The results confirm that the prototype devices can operate efficiently at both ends of the system and the membrane can be excited effectively by the air column. Such transducers are ideally matched to air and also offer the potential to be used with other load media.
ORCID iDs
Campbell, Ewan Fraser, Galbraith, Walter ORCID: https://orcid.org/0000-0002-5620-7807 and Hayward, Gordon;-
-
Item type: Book Section ID code: 44738 Dates: DateEvent2007PublishedSubjects: Technology > Electrical engineering. Electronics Nuclear engineering Department: Faculty of Engineering > Electronic and Electrical Engineering Depositing user: Pure Administrator Date deposited: 10 Sep 2013 13:20 Last modified: 11 Nov 2024 14:52 URI: https://strathprints.strath.ac.uk/id/eprint/44738