Picture of mobile phone running fintech app

Fintech: Open Access research exploring new frontiers in financial technology

Strathprints makes available Open Access scholarly outputs by the Department of Accounting & Finance at Strathclyde. Particular research specialisms include financial risk management and investment strategies.

The Department also hosts the Centre for Financial Regulation and Innovation (CeFRI), demonstrating research expertise in fintech and capital markets. It also aims to provide a strategic link between academia, policy-makers, regulators and other financial industry participants.

Explore all Strathclyde Open Access research...

The effect of direct axis current on the performance of the synthetic loading technique

Abbas, A. Y. M. and Fletcher, J. E. (2011) The effect of direct axis current on the performance of the synthetic loading technique. IEEE Transactions on Energy Conversion, 26 (1). pp. 115-121. ISSN 0885-8969

Full text not available in this repository. Request a copy from the Strathclyde author

Abstract

Synthetic loading is a technique that forces the machine under test to operate at rated speed, torque, and flux without the need for the test machine to be connected to an external load. The technique has been successfully applied to permanent magnet machines but it requires an inverter voltampere (VA) rating that is 1.51 pu of the rated value due to the need for instantaneous phase currents and voltages that are higher than the rated value. In order to reduce the VA rating, it is possible to inject direct axis current. This has important consequences. It reduces the ac perturbation current thereby reducing the peak instantaneous phase current. Also, by reducing the ac perturbation current, the rotor speed variation is reduced, thereby reducing the instantaneous phase voltage requirement. Both these effects reduce the VA rating of the inverter. However, this paper demonstrates through simulation and experiment that such a scheme increases the iron losses in the machine. This is important as it alters the distribution of losses which is not a desired consequence. The effect of direct axis current on the iron loss and the machine efficiency during synthetic loading is assessed and evaluated as is the effect on the minimum dc link voltage and the inverter VA requirements used to conduct the synthetic loading technique. Simulation and experimental results are used to demonstrate the effects and validate the conclusions that while direct axis current injection reduces the inverter VA rating, it reduces the accuracy of the synthetic loading technique.