The Strathprints institutional repository is a digital archive of University of Strathclyde's Open Access research outputs. Strathprints provides access to thousands of Open Access research papers by Strathclyde researchers, including by researchers from the Physical Activity for Health Group based within the School of Psychological Sciences & Health. Research here seeks to better understand how and why physical activity improves health, gain a better understanding of the amount, intensity, and type of physical activity needed for health benefits, and evaluate the effect of interventions to promote physical activity.

Explore open research content by Physical Activity for Health...

A preliminary evaluation of a hydro-cast trans-femoral socket, a proof of concept

Buis, Arjan and Kamyab, Mojtaba and Hillman, Susan and Murray, Kevin and McGarry, Anthony (2017) A preliminary evaluation of a hydro-cast trans-femoral socket, a proof of concept. Prosthetics and Orthotics Open Journal, 1 (7). pp. 1-9.

[img]
Preview
Text (Buis-etal-POOJ-2017-preliminary-evaluation-of-a-hydro-cast-trans-femoral-socket)
Buis_etal_POOJ_2017_preliminary_evaluation_of_a_hydro_cast_trans_femoral_socket.pdf - Final Published Version
License: Creative Commons Attribution 3.0 logo

Download (1MB) | Preview

Abstract

This study reports on a research project that has utilised, for the first time, a Hydro-casting (HC) technique to create a prosthetic socket for a person with trans-femoral amputation. Outcome measurements of the HC socket were compared with a socket and prosthesis produced by conventional ischial containment (IC) technique. Comparisons were based on differences in a) stump-socket interface pressures during gait, b) whole body gait kinetics and kinematics c) femoral movement within the stump tissues relative to the socket during gait. These observations provided a snapshot of the biomechanical environment of the stump and socket interface and assess the feasibility of using these outcome measurements to highlight differences between the two socket designs. This study demonstrated that it is feasible to use the HC approach to produce a prosthesis that is acceptable to both user and clinician. Results showed similarities between interface pressures, kinetic and kinematic data for both socket designs. The use of ultrasound to detect femoral motion identified that the conventional design paradigm, claiming to stabilise the motion of the femur, may not actually achieve this goal. Additional research is required with larger population of people with a trans-femoral amputation to assess the long term impact of this novel approach.