Development and validation of LC-MS/MS method for the simultaneous determination of vitamin B1, B2, B6 and B12 using human plasma (commercially pooled) with hydrophilic interaction liquid chromatography (HILIC)
Gandhi, Varun and Akil, Lina and Ford, Steven and Al-Tannak, Naser F. and Khadra, Ibrahim (2026) Development and validation of LC-MS/MS method for the simultaneous determination of vitamin B1, B2, B6 and B12 using human plasma (commercially pooled) with hydrophilic interaction liquid chromatography (HILIC). Results in Chemistry, 28. 103505. ISSN 2211-7156 (https://doi.org/10.1016/j.rechem.2026.103505)
|
Preview |
Text.
Filename: Gandhi-etal-RIC-2026-Development-and-validation-of-LC-MS-MS-method-for-the-simultaneous-determination.pdf
Final Published Version License:
Download (4MB) | Preview |
Abstract
A simple, reliable and sensitive analytical method was developed and validated for the simultaneous determination of vitamin B1 (Thiamine Hydrochloride), B2((−)-Riboflavin), B6 (Pyridoxine Hydrochloride) and B12 (Cyanocobalamin) from commercially pooled human plasma using HPLC coupled with mass spectrometry (LC-MS/MS) using hydrophilic interaction chromatography (HILIC) technique. The analysis was carried out using a mobile phase consisting of ammonium acetate buffer in water and acetonitrile, operated in gradient mode with a HILIC column (L3, USP Column listing). Detection was performed in positive ion mode using electrospray ionisation (ESI). Sample extraction was done using a protein precipitation technique. The chromatographic method was validated according to ICH guideline Q2(R1) for limit of detection (LOD), linearity, robustness system suitability test and sample extraction method using ICH guideline M10 for selectivity, lower limit of quantification (LLOQ), accuracy, precision and matrix effect. The LLOQ concentration was 0.05, 0.8, 0.2, 5.0 ng/mL and LOD was 0.01, 0.4, 0.08, 3 ng/mL for vitamin B1, B2, B6 and B12 respectively. All vitamins showed reliable detection at the LOD level. The LLOQ levels cover the clinical range for vitamin B1, B2, B6 but limited to B12. The coefficient of determination (r2) was ≥0.99 for all vitamins, demonstrating linearity across the quantitation range of 0.2–50.0 ng/mL, 0.8–50.0 ng/mL, 0.05–5.0 ng/mL, 5.0–300.0 ng/mL for vitamin B6, B2, B1 and B12 respectively. The results of accuracy and precision, extraction recovery and matrix effect were acceptable, it was within 85–115% at all tested levels and CV% was ≤15% (n = 3). The robustness and system suitability test parameter met the acceptance criteria of r2 ≥ 0.99, confirming the method to be fit for purpose during the study.
ORCID iDs
Gandhi, Varun
ORCID: https://orcid.org/0009-0009-4743-1928, Akil, Lina
ORCID: https://orcid.org/0000-0003-4033-6548, Ford, Steven, Al-Tannak, Naser F. and Khadra, Ibrahim
ORCID: https://orcid.org/0000-0002-9846-1520;
-
-
Item type: Article ID code: 96623 Dates: DateEvent1 August 2026Published8 June 2026Published Online28 May 2026AcceptedSubjects: Science > Chemistry Department: Faculty of Science > Strathclyde Institute of Pharmacy and Biomedical Sciences Depositing user: Pure Administrator Date deposited: 24 Jun 2026 08:38 Last modified: 10 Nov 2026 02:03 URI: https://strathprints.strath.ac.uk/id/eprint/96623