A new method for measuring structural limb-length discrepancy : A quasi-experimental study
Atallah, Huthaifa and Qufabz, Titeana and Alfatafta, Mahmoud and Alshawabka, Amneh and Yasin, Mohamad Samih and Samarah, Omar Q. and McGarry, Anthony and Molics, Bálint (2026) A new method for measuring structural limb-length discrepancy : A quasi-experimental study. Journal of Clinical Medicine, 15 (11). 4309. ISSN 2077-0383 (https://doi.org/10.3390/jcm15114309)
Preview |
Text.
Filename: Atallah-etal-JCM-2026-A-new-method-for-measuring-structural-limb-length-discrepancy.pdf
Final Published Version License:
Download (10MB)| Preview |
Abstract
Background/Objectives: Limb-length discrepancy (LLD) is a relatively common condition, with structural LLD characterized by true shortening of a bony structure. Although various clinical and radiological methods are available, none rely exclusively on position of malleoli relative to one another. This study aims to introduce a novel method for measuring structural LLD using malleoli in conjunction with a ruler. A quasi-experimental study. Methods: Eighteen participants with structural LLD were recruited from an orthopaedic clinic. Each participant underwent four tests: Paired Medial Malleolus Level Test (PMMLT) (new method), measuring tape method (Anterior Superior Iliac Spine (ASIS) to Medial Malleoli (MM), standing-block test, and full-length standing (long bone) radiography. Validity was assessed against radiography. Results: The mean ± SD LLD measured by radiography was 2.99 ± 1.69 cm. Corresponding values were obtained with the PMMLT (2.98 ± 1.69 cm), measuring tape method (2.95 ± 1.66 cm), and the standing-block test (2.92 ± 1.73 cm). No significant differences were found among the methods (χ2(3) = 3.43, p = 0.330). Correlations with radiography were very strong (PMMLT r = 0.996; measuring tape method r = 0.990; standing-block test r = 0.991; all p < 0.001). PMMLT showed negligible bias (−0.01 cm), the narrowest 95% limits of agreement (−0.32 to 0.30 cm), and the lowest RMSE (0.15 cm). Conclusions: The PMMLT demonstrates accuracy and practicality while being simple, cost-effective, and free of radiation exposure, making it a valuable alternative for clinical assessment of LLD in settings where imaging is unavailable or contraindicated.
ORCID iDs
Atallah, Huthaifa, Qufabz, Titeana, Alfatafta, Mahmoud, Alshawabka, Amneh, Yasin, Mohamad Samih, Samarah, Omar Q., McGarry, Anthony
ORCID: https://orcid.org/0000-0002-0738-5906 and Molics, Bálint;
-
-
Item type: Article ID code: 96496 Dates: DateEvent1 June 2026Published30 May 2026AcceptedSubjects: Medicine > Biomedical engineering. Electronics. Instrumentation Department: Faculty of Engineering > Biomedical Engineering Depositing user: Pure Administrator Date deposited: 16 Jun 2026 08:10 Last modified: 31 Jul 2026 01:49 URI: https://strathprints.strath.ac.uk/id/eprint/96496
Tools
Tools






