Single-pulse Gy-scale irradiation of biological cells at 1013 Gy s−1 average dose-rates from a laser-wakefield accelerator

McAnespie, C.A. and Chaudhary, P. and Streeter, M.J.V. and Botchway, S.W. and Bourgeois, N. and Calvin, L. and Cavanagh, N. and Fleck, K. and Jaroszynski, D. and Kettle, B. and Lupu, A.M. and Mangles, S.P.D. and McMahon, S.J. and Mill, J. and Needham, S.R. and Rajeev, P.P. and Sarma, J. and Prise, K.M. and Sarri, G. (2025) Single-pulse Gy-scale irradiation of biological cells at 1013 Gy s−1 average dose-rates from a laser-wakefield accelerator. Physics in Medicine & Biology, 70 (15). 155001. (https://doi.org/10.1088/1361-6560/adec36)

[thumbnail of McAnespie-etal-PMB-2025-Single-pulse-Gy-scale-irradiation-of-biological-cells]
Preview
Text. Filename: McAnespie-etal-PMB-2025-Single-pulse-Gy-scale-irradiation-of-biological-cells.pdf
Final Published Version
License: Creative Commons Attribution 4.0 logo

Download (2MB)| Preview

Abstract

Objective. We report on the first experimental characterisation of a laser-wakefield accelerator able to deliver, in a single pulse, doses in excess of 1 Gy on timescales of the order of a hundred femtoseconds, reaching unprecedented average dose-rates of up to 1013 Gy s−1. Approach. The irradiator is demonstrated to deliver doses tuneable up to 2.2 Gy in a cm2 area and with a high degree of longitudinal and transverse uniformity in a single irradiation. Main results. Proof-of-principle irradiation of patient-derived glioblastoma stem-like cells and human skin fibroblast cells show indications of a differential cellular response, when compared to reference irradiations at conventional dose-rates. These include a statistically significant increase in relative biological effectiveness (1.40 ± 0.08 at 50% survival for both cell lines) and a significant reduction of the relative radioresistance of tumour cells. Data analysis provides preliminary indications that these effects might not be fully explained by induced oxygen depletion in the cells but may be instead linked to a higher complexity of the damages triggered by the ultra-high density of ionising tracks of femtosecond-scale radiation pulses. Significance. These results demonstrate an integrated platform for systematic radiobiological studies at unprecedented beam durations and dose-rates, a unique infrastructure for translational research in radiobiology at the femtosecond scale.

ORCID iDs

McAnespie, C.A., Chaudhary, P., Streeter, M.J.V., Botchway, S.W., Bourgeois, N., Calvin, L., Cavanagh, N., Fleck, K., Jaroszynski, D. ORCID logoORCID: https://orcid.org/0000-0002-3006-5492, Kettle, B., Lupu, A.M., Mangles, S.P.D., McMahon, S.J., Mill, J., Needham, S.R., Rajeev, P.P., Sarma, J., Prise, K.M. and Sarri, G.;