Picture of DNA strand

Pioneering chemical biology & medicinal chemistry through Open Access research...

Strathprints makes available scholarly Open Access content by researchers in the Department of Pure & Applied Chemistry, based within the Faculty of Science.

Research here spans a wide range of topics from analytical chemistry to materials science, and from biological chemistry to theoretical chemistry. The specific work in chemical biology and medicinal chemistry, as an example, encompasses pioneering techniques in synthesis, bioinformatics, nucleic acid chemistry, amino acid chemistry, heterocyclic chemistry, biophysical chemistry and NMR spectroscopy.

Explore the Open Access research of the Department of Pure & Applied Chemistry. Or explore all of Strathclyde's Open Access research...

Validation of a district energy system model using field measured data

Talebi, Behrang and Haghigat, Fariborz and Tuohy, Paul Gerard and Mirzaie, Parham (2017) Validation of a district energy system model using field measured data. Energy. ISSN 1873-6785

[img]
Preview
Text (Talebi-etal-Energy-2017-Validation-of-a-district-energy-system-model)
Talebi_etal_Energy_2017_Validation_of_a_district_energy_system_model.pdf
Accepted Author Manuscript
License: Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 logo

Download (2MB)| Preview

    Abstract

    Load prediction is the first step in designing an efficient community district heating system (CDHS). Even though, several methods have been developed to predict the heating demand profile of buildings, there is a lack of method that can predict this profile for a large-scale community with a numerous user types in a timely manner and with an appropriate level of precision. It, first briefly describes the 4-step procedure developed earlier, utilizing a Multiple Non-Linear Regression (MNLR) method, for predicting the heating demand profile of district, followed by description of the community structure, and its district system. It also reports the field measurement procedure for collecting the data required and the preliminary analysis data. Results obtained from a continuous monitoring of the CDHS over a two-year period is employed to validate the accuracy of the developed model in the predicting the CDHS’s heating load profile. Finally, using the 4-step procedure, the district’s energy demand profile is predicted, and compared with both the measured data and the initial prediction. The outcome shows a less than 11.2% in the mean square root error (MSRE) of the predicted and measured load profiles.