The Strathprints institutional repository is a digital archive of University of Strathclyde's Open Access research outputs. Strathprints provides access to thousands of Open Access research papers by University of Strathclyde researchers, including by Strathclyde researchers from the Department of Computer & Information Sciences involved in researching exciting new applications for mobile and smartphone technology. But the transformative application of mobile technologies is also the focus of research within disciplines as diverse as Electronic & Electrical Engineering, Marketing, Human Resource Management and Biomedical Enginering, among others.

Explore Strathclyde's Open Access research on smartphone technology now...

In vitro assessment of the lenz effect on heart valve prosthesis at 1.5T

Edwards, Maria-Benedicta and McLean, John and Solomonidis, Stephanos and Condon, Barry and Gourlay, Terence (2015) In vitro assessment of the lenz effect on heart valve prosthesis at 1.5T. Journal of Magnetic Resonance Imaging, 41 (1). pp. 74-82. ISSN 1053-1807

Full text not available in this repository. Request a copy from the Strathclyde author

Abstract

Increasing numbers of patients with cardiac valve prostheses are being referred for magnetic resonance imaging (MRI) despite concerns about the potential for functional valve impedance due to Lenz forces. This study aims to determine, in vitro, the occurrence of Lenz forces on 9 heart valve prostheses at 1.5 T and assess the risk of impedance of valve function. A specially designed hydro-pneumatic system was used to record pressure changes across the valve indicative of any MR induced alteration in leaflet performance. Nine cardiac valve prostheses were exposed to the B0 field at 1.5 T. Each valve was advanced through the B0 field and continuous signals from high frequency pressure transducers were recorded and pressure drops across the valve were assessed using time correction superimposition. The delta p across the valve was assessed as a marker of any MRI induced alteration in leaflet performance. All prostheses produced sinusoidal waveforms. Profiles were asymmetrical and there was no consistency in complex shape and valve type/sub-group. Irregularities in pressure profiles of 4 prostheses were detected indicating resistance of the occluder to the B0 field. This study provides empirical evidence of the Lenz Effect on cardiac valve prostheses exposed to the MR B0 field causing functional valve impedance and increasing the risk of valvular regurgitation and reduced cardiac output. Thus, it is essential to consider the potential for the Lenz Effect when scanning cardiac valve implant patients in order to safeguard their wellbeing.