Strathprints Home | Open Access | Browse | Search | User area | Copyright | Help | Library Home | SUPrimo

Errors in measuring sagittal arch kinematics of the human foot with digital fluoroscopy

Wearing, S.C. and Smeathers, J.E. and Yates, B. and Sullivan, P.M. and Urry, S.R. and Dubois, P. (2005) Errors in measuring sagittal arch kinematics of the human foot with digital fluoroscopy. Gait and Posture, 21 (3). pp. 326-332. ISSN 0966-6362

Full text not available in this repository. (Request a copy from the Strathclyde author)

Abstract

Although fluoroscopy has been used to evaluate motion of the foot during gait, the accuracy and precision of fluoroscopic measures of osseous structures of the foot has not been reported in the literature. This study reports on a series of experiments that quantify the magnitude and sources of error involved in digital fluoroscopic measurements of the medial longitudinal arch. The findings indicate that with a global distortion correction procedure, errors arising from image distortion can be reduced threefold to 0.2° for angular measurements and to 0.1 mm for linear measures. The limits of agreement for repeated angular measures of the calcaneus and first metatarsal were ±0.5° and ±0.6°, indicating that measurement error was primarily associated with the manual process of digitisation. While the magnitude of the residual error constitutes about ±2.5% of the expected 20° of movement of the calcaneus and first metatarsal, out-of-plane rotation may potentially contribute the greatest source of error in fluoroscopic measures of the foot. However, even at the extremes of angular displacement (15°) reported for the calcaneum during running gait, the root mean square (RMS) error was only about 1°. Thus, errors associated with fluoroscopic imaging of the foot appear to be negligible when compared to those arising from skin movement artefact, which typically range between 1.5 and 4 mm (equating to errors of 2° to 17° for angular measures). Fluoroscopy, therefore, may be a useful technique for analysing the sagittal movement of the medial longitudinal arch during the contact phase of walking.

Item type: Article
ID code: 4800
Keywords: accuracy, precision, feet, x-ray, motion analysis, bioengineering, Bioengineering
Subjects: Technology > Engineering (General). Civil engineering (General) > Bioengineering
Department: Faculty of Engineering > Bioengineering
Related URLs:
    Depositing user: Strathprints Administrator
    Date Deposited: 24 Nov 2007
    Last modified: 12 Mar 2012 10:41
    URI: http://strathprints.strath.ac.uk/id/eprint/4800

    Actions (login required)

    View Item