The Strathprints institutional repository is a digital archive of University of Strathclyde's Open Access research outputs. Strathprints provides access to thousands of Open Access research papers by Strathclyde researchers, including by researchers from the Physical Activity for Health Group based within the School of Psychological Sciences & Health. Research here seeks to better understand how and why physical activity improves health, gain a better understanding of the amount, intensity, and type of physical activity needed for health benefits, and evaluate the effect of interventions to promote physical activity.

Explore open research content by Physical Activity for Health...

Comparison of different piezoelectric materials for the design of embedded transducers for structural health monitoring applications

Hailu, B. and Hayward, Gordon and Gachagan, Anthony and McNab, Alistair and Farlow, Roger (2000) Comparison of different piezoelectric materials for the design of embedded transducers for structural health monitoring applications. In: 2000 IEEE Ultrasonics Symposium Proceedings. IEEE, New York, pp. 1009-1012. ISBN 0780363655

Full text not available in this repository. Request a copy from the Strathclyde author

Abstract

This paper describes the design requirements for embedded piezoelectric plate transducers suitable for generating efficient, uni-modal Lamb wave signals in plate structures. Three piezoelectric materials are considered, modified lead titanate, lead zirconate titanate, and polyvinylidene difluoride, in conjunction with different 1-3 piezoelectric composite configurations. Finite element modelling was used to predict the various Lamb wave modes generated by transducers embedded in a hard-set epoxy plate. Accordingly, the design requirements for successful generation of the zeroth order symmetric (So) Lamb wave mode have been identified. It is shown that the transducer position and the orientation within the host structure, and the appropriate choice of the excitation frequency of the Lamb wave, relative to the structural resonances, are the crucial design parameters for the success of Lamb wave mode selectivity. The amplitude of the Lamb wave signal can be optimised by appropriate choice of the transducer lateral dimension. To validate the theoretical findings, transducers were embedded in both hard-set epoxy and uni-directional carbon fibre plates. Successful generation of the So mode is demonstrated by means of a scanning laser vibrometer.