Picture of virus under microscope

Research under the microscope...

The Strathprints institutional repository is a digital archive of University of Strathclyde research outputs.

Strathprints serves world leading Open Access research by the University of Strathclyde, including research by the Strathclyde Institute of Pharmacy and Biomedical Sciences (SIPBS), where research centres such as the Industrial Biotechnology Innovation Centre (IBioIC), the Cancer Research UK Formulation Unit, SeaBioTech and the Centre for Biophotonics are based.

Explore SIPBS research

Evaluation of methods aimed at complete removal of template from molecularly imprinted polymers

Ellwanger, A. and Berggren, C. and Bayoudh, S. and Crecenzi, C. and Karlsson, L. and Owens, P.K. and Ensing, K. and Cormack, P. and Sherrington, D.C. and Sellergren, B. (2001) Evaluation of methods aimed at complete removal of template from molecularly imprinted polymers. Analyst, 126 (6). pp. 784-792. ISSN 0003-2654

Full text not available in this repository. (Request a copy from the Strathclyde author)

Abstract

Polymers imprinted with clenbuterol were used to study the influence of various post-polymerization treatments [e.g., thermal annealing, microwave assisted extraction (MAE), Soxhlet extraction and supercritical fluid template desorption] on the bleeding of residual template. The aim of the study was to reduce the bleeding to levels that would allow the use of the materials as affinity phases for extraction of clenbuterol from bovine urine at concentrations below 1 ng ml(-1). After treatment, the clenbuterol imprinted polymers were packed into solid-phase extraction columns and the bleeding was estimated by quantifying the amount of template released in 10 ml of methanol-acetic acid (9 + 1 v/v). This was followed by an assessment of selectivity and recovery in comparison with non-treated material. The lowest bleeding level was found after MAE using 100% trifluoroacetic acid for 3 x 20 min at 100 degreesC. The collected eluate contained in this case 3 ng ml(-1) of clenbuterol. The same material was subsequently used for the extraction of clenbuterol from spiked bovine urine. The resulting selectivity and recovery were lower compared with those obtained using the untreated material. A milder but still efficient method to reduce the bleeding level was found to be MAE with formic acid. In this case a bleeding level of 14 ng ml(-1) was found after only a 1 h extraction time. In a second model system, using a polymer imprinted with l-phenylalanine anilide, the bleeding was reduced to a similar level by extensive on-line washing in good swelling solvents containing acid or base additives and after thermal annealing of the polymers in the dry state.