The Strathprints institutional repository is a digital archive of University of Strathclyde's Open Access research outputs. Strathprints provides access to thousands of Open Access research papers by University of Strathclyde researchers, including by Strathclyde researchers from the Department of Computer & Information Sciences involved in researching exciting new applications for mobile and smartphone technology. But the transformative application of mobile technologies is also the focus of research within disciplines as diverse as Electronic & Electrical Engineering, Marketing, Human Resource Management and Biomedical Enginering, among others.

Explore Strathclyde's Open Access research on smartphone technology now...

Hands-off and hands-on casting consistency of amputee below knee sockets using magnetic resonance imaging

Safari, Reza and Buis, Adrianus and Rowe, Philip and McFadyen, Angus (2013) Hands-off and hands-on casting consistency of amputee below knee sockets using magnetic resonance imaging. ScientificWorld Journal, 2013.

[img] PDF (Hands-Off and Hands-On Casting Consistency of Amputee below Knee Sockets Using Magnetic Resonance Imaging)
hands_on_Hands_off_MRI_studi.pdf - Preprint

Download (3MB)

Abstract

Residual limb shape capturing (Casting) consistency has a great influence on the quality of socket fit. Magnetic Resonance Imaging was used to establish a reliable reference grid for inter cast and intra cast shape and volume consistency of two common casting methods, Hands-off and Hands-on. Design: Residual limbs were cast for twelve people with a unilateral below knee amputation and scanned twice for each casting concept. Subsequently, all four volume images of each amputee were semi-automatically segmented and registered to a common coordinate system using the tibia and then the shape and volume differences were calculated. Results: The results show that both casting methods have intra cast volume consistency and there is no significant volume difference between the two methods. Inter and intra cast mean volume differences were not clinically significant based on the volume of one sock criteria. Neither the Hands-off nor the Hands-on method resulted in a consistent residual limb shape as the coefficient of variation of shape differences was high. Conclusion: The resultant shape of the residual limb in the Hands-off casting was variable but the differences were not clinically significant. For the Hands-on casting, shape differences were equal to the maximum acceptable limit for a poor socket fit.