Picture of athlete cycling

Open Access research with a real impact on health...

The Strathprints institutional repository is a digital archive of University of Strathclyde's Open Access research outputs. Strathprints provides access to thousands of Open Access research papers by Strathclyde researchers, including by researchers from the Physical Activity for Health Group based within the School of Psychological Sciences & Health. Research here seeks to better understand how and why physical activity improves health, gain a better understanding of the amount, intensity, and type of physical activity needed for health benefits, and evaluate the effect of interventions to promote physical activity.

Explore open research content by Physical Activity for Health...

Affordable clinical gait analysis : an assessment of the marker tracking accuracy of a new low-cost optical 3D motion analysis system

Carse, Bruce and Meadows, Barry and Bowers, Roy and Rowe, Philip (2013) Affordable clinical gait analysis : an assessment of the marker tracking accuracy of a new low-cost optical 3D motion analysis system. Physiotherapy. pp. 347-351. ISSN 0031-9406

Full text not available in this repository. Request a copy from the Strathclyde author

Abstract

3D motion analysis represents a method of collecting objective, accurate and repeatable gait data, however the high cost of equipment inhibits its widespread use in routine clinical practice. OBJECTIVE: To determine the marker tracking accuracy of a new low-cost optical 3D motion analysis system. Comparative between-system study. SETTING: Clinical motion analysis laboratories. METHODS: A rigid cluster of four reflective markers was used to compare a low-cost Optitrack 3D motion analysis system against two more expensive systems (Vicon 612 and Vicon MX). Accuracy was measured by comparing the mean vector magnitudes (between each combination of markers) for each system, and reliability was measured through the coefficients of variation (CV). Gaps in the marker trajectories, which are considered undesirable, were also counted. RESULTS: In terms of accuracy, the largest disagreement between mean vector magnitudes for Optitrack and Vicon MX was 2.2%. The largest disagreement between Vicon 612 and Vicon MX was 2.1%. Regarding reliability, the mean CV was lowest in Vicon MX (0.3%) and similar in the Vicon 612 (2.5%) and Optitrack (2.3%) systems. The number of trajectory gaps for the Vicon MX, Vicon 612 and Optitrack systems were; zero, six and 11 respectively. The Optitrack system provides a low-cost 3D motion analysis system that can offer marker tracking accuracy and reliability which is comparable with an older and still widely used system (Vicon 612). Further development work is required before Optitrack can be used for full 3D gait analysis by physiotherapists and other health professionals.