Picture of smart phone in human hand

World leading smartphone and mobile technology research at Strathclyde...

The Strathprints institutional repository is a digital archive of University of Strathclyde's Open Access research outputs. Strathprints provides access to thousands of Open Access research papers by University of Strathclyde researchers, including by Strathclyde researchers from the Department of Computer & Information Sciences involved in researching exciting new applications for mobile and smartphone technology. But the transformative application of mobile technologies is also the focus of research within disciplines as diverse as Electronic & Electrical Engineering, Marketing, Human Resource Management and Biomedical Enginering, among others.

Explore Strathclyde's Open Access research on smartphone technology now...

Novel ultrafiltration technique for blood conservation in cardiac operations

Gourlay, Terry and Gunaydin, Serdar (2013) Novel ultrafiltration technique for blood conservation in cardiac operations. Annals of Thoracic Surgery, 95 (6). pp. 2148-2151. ISSN 0003-4975

Full text not available in this repository. Request a copy from the Strathclyde author

Abstract

The performance characteristics and clinical outcome of a novel hemoconcentrator, the HemoSep (Brightwake, Nottingham, United Kingdom), for reusing salvaged blood postoperatively were evaluated. HemoSep concentrates blood by removing the fluid component from a pooled volume of blood salvaged at the end of the operation from the heart-lung machine. During a 6-month period, 102 patients were prospectively randomized into two groups. In group 1 (n = 52), salvaged blood in the venous reservoir after the cessation of cardiopulmonary bypass was reused by the HemoSep device and the processed blood was retransfused to the patients. In group 2 (n = 50), the control group, the operation proceeded using conventional method without using the hemoconcentrator. The mean amount of processed blood was 775 ± 125 mL. The efficacy of the HemoSep device was confirmed by the percentage concentration of the hematocrit at 15 and 40 minutes. Serum albumin and factor VII levels were concentrated more than threefold at 40 minutes vs baseline measurements. Patients who received processed blood had significantly less need for an allogeneic transfusion. The HemoSep device functions as designed and without technical failures, offering a complementary technique in blood management during cardiac operations.