Picture of smart phone in human hand

World leading smartphone and mobile technology research at Strathclyde...

The Strathprints institutional repository is a digital archive of University of Strathclyde's Open Access research outputs. Strathprints provides access to thousands of Open Access research papers by University of Strathclyde researchers, including by Strathclyde researchers from the Department of Computer & Information Sciences involved in researching exciting new applications for mobile and smartphone technology. But the transformative application of mobile technologies is also the focus of research within disciplines as diverse as Electronic & Electrical Engineering, Marketing, Human Resource Management and Biomedical Enginering, among others.

Explore Strathclyde's Open Access research on smartphone technology now...

Computational modelling to optimize the hybrid configuration for hypoplastic left heart syndrome

Young, Andrew and Gourlay, Terry and McKee, Sean and Danton, Mark H.D. (2013) Computational modelling to optimize the hybrid configuration for hypoplastic left heart syndrome. European Journal of Cardio-Thoracic Surgery, 44 (4). pp. 664-672. ISSN 1010-7940

Full text not available in this repository. Request a copy from the Strathclyde author

Abstract

Hybrid palliation for hypoplastic left heart syndrome (HLHS) is associated with mortality and late ventricular dysfunction. Increased ventricular workload and coronary perfusion limitation may be the important factors. Using mathematical modelling, this study investigated the effects of differing hybrid configurations on the demands on this single ventricle circulation. A multicompartmental Windkessel model of hybrid HLH-aortic atresia circulation was adopted, with a time-varying elastance representing ventricular functionality. The effects of diameter increases in bilateral pulmonary artery bandings (PABs) (+0.5, 2.5-4 mm) and ductal stent (+1, 4-10 mm) on cardiovascular haemodynamics, systemic oxygenation and ventricular energetics were assessed. Simulations showed that an increase in PAB diameter of 2.5-4 mm resulted in an increased Q (0.61-2.66), and diastolic stent backflow (-0.2 to -0.78 l/min) with reduced systemic perfusion (0.82-0.77 l/min) and diastolic pressures (48.3-41.2 mmHg). Arterial and venous saturations increased, SaO2 (%) was 62-88 and SvO(2) 41-65. To maintain mean systemic pressures, substantial increases in cardiac output (1.3-2.8 l/min) and ventricular stroke work (576-1360 mmHg ml) were required. A decrease in the ductal stent diameter over the range 10-7 mm had a negligible haemodynamic effect: reduced systemic systolic pressure (77-72 mmHg) and increase in ventricular stroke work (781-790 mmHg ml). When the ductal diameter was restricted to <7 mm, it resulted in a significant reduced systemic flow and increased stroke work. Optimal hybrid configuration was defined at PAB 3 mm and ductal stent ≥7 mm. In this model, increasing the PAB diameter, or a stent diameter <7 mm, substantially increased single ventricle workload and reduced systemic perfusion and diastolic pressure. This may compromise myocardial oxygen demand-supply, particularly in the setting of retrograde-dependent coronary perfusion.