The Strathprints institutional repository is a digital archive of University of Strathclyde's Open Access research outputs. Strathprints provides access to thousands of Open Access research papers by University of Strathclyde researchers, including by Strathclyde researchers from the Department of Computer & Information Sciences involved in researching exciting new applications for mobile and smartphone technology. But the transformative application of mobile technologies is also the focus of research within disciplines as diverse as Electronic & Electrical Engineering, Marketing, Human Resource Management and Biomedical Enginering, among others.

Explore Strathclyde's Open Access research on smartphone technology now...

Influence of condenser conditions on organic rankine cycle load characteristics

Erhart, Tobias Gabriel and Eicker, Ursula and Infield, David (2013) Influence of condenser conditions on organic rankine cycle load characteristics. Journal of Engineering for Gas Turbines and Power, 135 (4). ISSN 0742-4795

Full text not available in this repository. (Request a copy from the Strathclyde author)

Abstract

A 7 MWth combined heat and power plant (CHP) based on an organic Rankine cycle (ORC) with 5.3 MWth and 1 MWel nominal output is analyzed. A district heating system serves as heat sink; the entire system is heat-led. Two examples for winter and summer operation are shown. The observed characteristics of the condenser are compared to results of a theoretical model. Variable mass flows, temperature levels (72 °C–95 °C) and temperature spreads result in varying condensation temperatures and pressure levels in the condenser (90 mbar to 150 mbar). High mass flows on the secondary side and related low temperature spreads improve the heat transfer and increase the condensation rate in the condenser. The monitoring data support the findings of a steady-state condenser model. As a consequence, advantageous load profiles according to the pressure characteristic of the system can be reached. Live steam pressure, pressure difference across the turbine, and flow rate increase. The effect on the electric efficiency is one percentage point in summer and 1.5 percentage points in winter, which translates to a difference in the electric yield of the cycle of about 10%. Furthermore, the data show that the transient sink conditions cause unsteady operation for the entire cycle.