Picture of a black hole

Strathclyde Open Access research that creates ripples...

The Strathprints institutional repository is a digital archive of University of Strathclyde's Open Access research outputs. Strathprints provides access to thousands of research papers by University of Strathclyde researchers, including by Strathclyde physicists involved in observing gravitational waves and black hole mergers as part of the Laser Interferometer Gravitational-Wave Observatory (LIGO) - but also other internationally significant research from the Department of Physics. Discover why Strathclyde's physics research is making ripples...

Strathprints also exposes world leading research from the Faculties of Science, Engineering, Humanities & Social Sciences, and from the Strathclyde Business School.

Discover more...

A theoretical model of an electrostatic ultrasonic transducer incorporating resonating conduits

Walker, A.J. and Mulholland, A.J. and Whitely, S. (2010) A theoretical model of an electrostatic ultrasonic transducer incorporating resonating conduits. IMA Journal of Applied Mathematics, 75 (5). pp. 796-810. ISSN 0272-4960

Full text not available in this repository. (Request a copy from the Strathclyde author)

Abstract

This article considers a theoretical model of an electrostatic transducer with resonating conduits connected to the cavities in the backplate. A 1D (in space) model is proposed so that the inverse problem of optimizing the design parameters of the device for a desired output is not computationally prohibitive. The mathematical model is described based on matching the acoustic impedances at each interface of the device. The resulting ordinary differential equation is solved to give the frequency domain response of the system and the pressure output at the membrane. Derivation of the electrical impedance, transmission voltage response and reception force response is also provided. The model is implemented to compare a standard device (no conduits coming from the cavity) with a device with one conduit coming from the cavity. The model output is collated with experimental data and then used to analyse the maximum pressure output for various cavity and conduit dimensions. The results show a significant dependence of the device performance on the cavity and conduit dimensions. The incorporation of fluid-filled conduits onto the cavities in the backplate significantly increases the pressure output as well as the transmission and reception sensitivities. The results show that a practical transducer design could be achieved by suitable choices of device geometry and the physical properties of the materials employed.