Picture of a black hole

Strathclyde Open Access research that creates ripples...

The Strathprints institutional repository is a digital archive of University of Strathclyde's Open Access research outputs. Strathprints provides access to thousands of research papers by University of Strathclyde researchers, including by Strathclyde physicists involved in observing gravitational waves and black hole mergers as part of the Laser Interferometer Gravitational-Wave Observatory (LIGO) - but also other internationally significant research from the Department of Physics. Discover why Strathclyde's physics research is making ripples...

Strathprints also exposes world leading research from the Faculties of Science, Engineering, Humanities & Social Sciences, and from the Strathclyde Business School.

Discover more...

Dynamic interface pressure distributions of two transtibial prosthetic socket concepts

Buis, A.W.P. and Dumbleton, T. and McHugh, B.F. and McFadyen, A. and McKay, G. and Murray, K. and Sexton, Sandra and , Action medical research (Funder) (2009) Dynamic interface pressure distributions of two transtibial prosthetic socket concepts. Journal of Rehabilitiation Research and Development, 46 (3). pp. 405-415. ISSN 0748-7711

Full text not available in this repository. (Request a copy from the Strathclyde author)

Abstract

Abstract - In this study, we investigated and compared the dynamic interface pressure distribution of hands-off and hands-on transtibial prosthetic systems by means of pressure mapping. Of the 48 established unilateral amputees recruited, half (n = 24) had been wearing pressure-cast prostheses (IceCast Compact) and the other half (n = 24) had been wearing hand-cast sockets of the patellar tendon bearing design. We measured the dynamic pressure profile of more than 90% of the area within each prosthetic socket by means of four Tekscan F-Scan socket transducer arrays. We compared the interface pressure between socket concepts. We found that the distribution of dynamic pressure at the limb-socket interface was similar for the two intervention (socket prescription) groups. However, a significant difference was found in the magnitude of the interface pressure between the two socket concepts; the interface pressures recorded in the hands-off sockets were higher than those seen in the hands-on concept. Despite the differences in interface pressure, the level of satisfaction with the sockets was similar between subject groups. The sockets instrumented for this study had been in daily use for at least 6 months, with no residual-limb health problems.